Stahl-143544  8290/3-M25 price

Technical information

Manufacturer Stahl
Part number 143544 8290/3-M25
Inner Code 40542
Description (Stopping Plug explosion-protected Type : 8290/3-M25 Material : Polyamide Thread size : M25 Drive : Hexagon socket Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e IIC Gb Dust explosion protection : II 2 D Ex tb IIIC Db Min. ambient temperature : -60 °C Max. ambient temperature : +80 °C Packaging unit : 100 CCT No.: 85389099 DE Net weigth: 0,700 KG)
Weight: 1

Don't hesitate to contact us!

Looking for industrial spare parts?

Other Stahl products

  • 8602/3

    Pushbutton

  • 8602 STOP

    (Button label Label marking : STOP Colour of label : red For further information, see : www.r-stahl.com Web code 8082A)

  • 8602A0727 1-2-R-V

    (Rotary handle, small lockable explosion-protected Enclosure material : Polyamide Seal : Standard Mounting : with threaded Switching function : latching Number of switching positions : 2 Construction type : vertical Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 For further information, see : www.r-stahl.com Web code 8082A)

  • 158356

    Max. Voltage Uo : 28 VMax. Current Io : 100 mAMax. Demand Po : 700 mWNumber of channels : 1Polarity : negative polarityApplication range (Zone) : 2Gas explosion protection : II 3 (1) G Ex nA[ia Ga]Dust explosion protection : II (1) D [Ex ia Da] IIICRated operational voltage DC : 24 VMaximum output current Imax : 75 mAFor further information, see : www.r-stahl.com Web code 9001A

  • 9001/01-168-020-101 (158555)

    Single-channel safety barriers explosion-protected

  • 9118/11-11-10 - OBSOLETE (REPLACED BY 9118/11-11-10)

    ics modul-mA isolating repeater(max vol.:8.7 V max. cur.:0.4 mA max. pow.:11mW power supp.:24 vDC)

  • 9160/13-11-11S

    BARRIER: PROTECTIVE, for receiving and transmitting UNIFIED SIGNALs POWER SUPPLY SENSOR, EEX IA IIC

  • 9160/13-11-11S

    (ISpac Isolating Repeater Transmitter Supply Unit Field Circuit Ex i explosion-protected Max. Voltage Uo : 27 V Max. Current Io : 88 mA Max. Demand Po : 576 mW Nominal voltage : 24 V DC Nominal current : 70 mA Power input_W : 1,7 W Number of channels : 1 Input : 0/4 ... 20 mA with HART Output : 0/4 ... 20 mA LFD relay : Yes Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Application range (Zone) : 2 Gas explosion protection : II 3 (1) G Ex nA nC [ia] IIC T4 Dust explosion protection : II (1) D [Ex iaD])

  • 9164/13-22-08

    mA-Trennübertrager

  • 207909 / 9165/16-11-10s

    iSPAC separation transformer

  • 201270/9165/16-11-11s

    Isolator analog output

  • 9170/10-11-11S

    BARRIER: PROTECTIVE, for receiving and transmitting UNIFIED SIGNALs

  • 9170/10-11-11S

    (ISpac Isolating Repeater Switching Repeater Field Circuit Ex i explosion-protected Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Nominal voltage : 24 V DC Nominal current : 33 mA Number of channels : 1 Output / channel : 2 change over contacts LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Application range (Zone) : 2 Gas explosion protection : II 3 (1) G Ex nAc nCc [ia] IIC T4 Dust explosion protection : II (1) D [Ex ia] IIIC)

  • 9170/10-12-21s

    (ISpac Switching amplifier Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Gas explosion protection : II (1) G [Ex ia] IIC Dust explosion protection : II (1) D [Ex ia] IIIC)

  • 9170/20-12-11S

    160293, IS PACIsolating RepeaterSwitching RepeaterField Circuit Ex iexplosion-protectedType : 9170/20-12-11sMax. Voltage Uo : 10,6 VMax. Current Io : 48 mAMax. Demand Po : 128 mWNominal voltage : 24 V DCNominal current : 33 mA Number of channels : 2Output / channel : 1 change over contactLFD relay : YesLine fault transparency : NoMin. ambient temperature : -20 °CMax. ambient temperature : +70 °CDust explosion protection : II (1) D [Ex ia] IIICFor further information, see : www.r-stahl.com Web code 9170ASwitching Repeater Series 9170, Field Circuit Ex i, dual channelBasic function: binary / digital inputIntrinsically safe input: [Ex ia] IICPower supply: 24 V DCInput: acc. to EN 60947-5-6 (NAMUR)Output / channel: 1 change-over contactConnection type: Screw terminals

  • 9176/20-12-00S

    (Binary output loop-powered IS pac)

  • 9182/10-51-11S / PN: 160546

    temperature transmitter

  • 9185/11-35-10

    FIELDBUS ISOLATING REPEATER

  • 9194/50-01

    (ISpac pac-Bus single element explosion-protected Nominal voltage : 24 V DC Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C)

  • 161887 / 9411/21-210-41

    ISBus Fieldbus Technology