Rotork - Z680412403
Please contact us to request a price quote for Rotork - Z680412403, or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Technical information
Manufacturer | Rotork |
---|---|
Part number | Z680412403 |
Inner Code | 3424324 |
Description | spare actuator |
Technical specification | IQ35 F16 A [IP68] 24RPM 380/3/50 Wiring diagram 100B0000 • ENCLOSURE: Watertight to IEC/BS EN 60529, IP66/IP68 - 20 metres/10 days. Terminal compartment sealed internally and externally ‘Double-Sealed’. • TEMPERATURE: -30° C to 70° C (-22° F to 158° F) subject to hazardous area certification where applicable (Watertight, FM, CSA EP) -20° C to 70° C (-4° F to 158° F) subject to hazardous area certification where applicable (ATEX, IECEx) • MOTOR: Three phase low inertia squirrel cage motor, class F insulation, incorporating thermostat protection. • SERVICE/DUTY RATING: Class A (On/Off), Class B (Inching), nominal 60 Starts at a rate not exceeding 600 starts per hour. 15 minutes rated based on a nominal torque of 33% of rated. • STARTER: Integral electrically and mechanically interlocked reversing contactors. • HAMMER BLOW: Drive incorporates lost motion ‘hammer-blow’, for releasing sticking valves. • SYNCROPHASE: Auto Phase rotation correction and lost phase protection on three phase supplies. • LOCAL CONTROLS: Black, Open/Close selector and Red, padlockable Local/Stop/Remote selector (stop remains available for site operational protection). • LOCAL INDICATION: Integral illuminated, digital valve position indicator showing 0.1% increments in position with closed and open limit symbols, torque, alarms and other status data. 3 LED's; red-open, yellow-intermediate, green-closed (can reverse), blinker and alarms configurable. • BATTERY SUPPORT - POWER OFF CONDITIONS: The battery is not required for position sensing it does however support the LCD display, operation of indication relays, commissioning and data logging functions in the absence of mains power. • POSITION SENSOR: Absolute encoder with 8000 turn, 0.1% resolution with built in redundancy, provides continuous high resolution position measurement which is fully maintained during manual operation and without a power supply or battery support. • ORIENTATION: Actuator can be mounted in any orientation, control cover including local controls and indication can be rotated in 90° increments to suit. • MANUAL OVERRIDE: Padlockable clutch lever, Handwheel clockwise to close, automatically disengages when motor starts and non-rotating during electric operation. • LUBRICATION: Gearcase oil filled for life – SAE80EP gear oil. • TORQUE SWITCHES: Adjustable electronic torque switches 40% to 100% of rated with start of travel bypass option. • COMMISSIONING: Travel limit setting, configuration of relays, alarms and other actuator settings carried out non-intrusively via an Infra-red/Bluetooth Setting Tool (one supplied with every order). Settings can be password protected. • DATA LOGGING/ASSET MANAGEMENT: Date/time stamped logging and display of operational events and trends, motor starts and valve torque profiles. Valve/actuator/gearbox data can be stored and service alarms configured. Data can also be downloaded via IrDA or Bluetooth to the supplied setting tool for upload to a PC and analysis using free InSight2 software. • CABLE ENTRIES: 3x M25 + 1x M40 (alternatively 3x 1” + 1x 1.5” NPT or 3x PG16 + 1x PG29). Cable glands not included in our scope of supply. • TERMINALS: M5 power and M4 control terminals, screws and washers supplied. Designed for ring tag crimped field wiring conductors up to 16.0mm² for power and 4.0mm² for controls. • PAINT FINISH: Polyester powder coating applied by electrostatic means to 100 micron nominal thickness. Colours: Handwheel/Hand Auto Lever/Base – Black. Housings/Covers - Grey (00-A-05) WIRING DIAGRAM Wiring diagram 100B0000 is described in IQ/IQT Control and Monitoring publication (PUB002-041) and includes: • CONTROL SUPPLY: 20 – 60VDC/40 – 120VAC or actuator derived 24VDC • CONTROL INPUTS: 6 inputs for open, close, stop/maintain, ESD and interlock signals • INDICATION CONTACTS: 4 volt-free (SPST) latching contacts (S1-S4), rated at 120VAC/30VDC, 5mA to 5A, each configurable NO or NC to signal one of the following; open/closed or intermediate positions, moving (continuous or pulsing), Handwheel operation, local selected, remote selected, open/close interlock active, ESD active, motor tripped on torque in mid travel/going • ENCLOSURE: Watertight to IEC/BS EN 60529, IP66/IP68 - 20 metres/10 days. Terminal compartment sealed internally and externally ‘Double-Sealed’. • TEMPERATURE: -30° C to 70° C (-22° F to 158° F) subject to hazardous area certification where applicable (Watertight, FM, CSA EP) -20° C to 70° C (-4° F to 158° F) subject to hazardous area certification where applicable (ATEX, IECEx) • MOTOR: Three phase low inertia squirrel cage motor, class F insulation, incorporating thermostat protection. • SERVICE/DUTY RATING: Class A (On/Off), Class B (Inching), nominal 60 Starts at a rate not exceeding 600 starts per hour. 15 minutes rated based on a nominal torque of 33% of rated. • STARTER: Integral electrically and mechanically interlocked reversing contactors. • HAMMER BLOW: Drive incorporates lost motion ‘hammer-blow’, for releasing sticking valves. • SYNCROPHASE: Auto Phase rotation correction and lost phase protection on three phase supplies. • LOCAL CONTROLS: Black, Open/Close selector and Red, padlockable Local/Stop/Remote selector (stop remains available for site operational protection). • LOCAL INDICATION: Integral illuminated, digital valve position indicator showing 0.1% increments in position with closed and open limit symbols, torque, alarms and other status data. 3 LED's; red-open, yellow-intermediate, green-closed (can reverse), blinker and alarms configurable. • BATTERY SUPPORT - POWER OFF CONDITIONS: The battery is not required for position sensing it does however support the LCD display, operation of indication relays, commissioning and data logging functions in the absence of mains power. • POSITION SENSOR: Absolute encoder with 8000 turn, 0.1% resolution with built in redundancy, provides continuous high resolution position measurement which is fully maintained during manual operation and without a power supply or battery support. • ORIENTATION: Actuator can be mounted in any orientation, control cover including local controls and indication can be rotated in 90° increments to suit. • MANUAL OVERRIDE: Padlockable clutch lever, Handwheel clockwise to close, automatically disengages when motor starts and non-rotating during electric operation. • LUBRICATION: Gearcase oil filled for life – SAE80EP gear oil. • TORQUE SWITCHES: Adjustable electronic torque switches 40% to 100% of rated with start of travel bypass option. • COMMISSIONING: Travel limit setting, configuration of relays, alarms and other actuator settings carried out non-intrusively via an Infra-red/Bluetooth Setting Tool (one supplied with every order). Settings can be password protected. • DATA LOGGING/ASSET MANAGEMENT: Date/time stamped logging and display of operational events and trends, motor starts and valve torque profiles. Valve/actuator/gearbox data can be stored and service alarms configured. Data can also be downloaded via IrDA or Bluetooth to the supplied setting tool for upload to a PC and analysis using free InSight2 software. • CABLE ENTRIES: 3x M25 + 1x M40 (alternatively 3x 1” + 1x 1.5” NPT or 3x PG16 + 1x PG29). Cable glands not included in our scope of supply. • TERMINALS: M5 power and M4 control terminals, screws and washers supplied. Designed for ring tag crimped field wiring conductors up to 16.0mm² for power and 4.0mm² for controls. • PAINT FINISH: Polyester powder coating applied by electrostatic means to 100 micron nominal thickness. Colours: Handwheel/Hand Auto Lever/Base – Black. Housings/Covers - Grey (00-A-05) WIRING DIAGRAM Wiring diagram 100B0000 is described in IQ/IQT Control and Monitoring publication (PUB002-041) and includes: • CONTROL SUPPLY: 20 – 60VDC/40 – 120VAC or actuator derived 24VDC • CONTROL INPUTS: 6 inputs for open, close, stop/maintain, ESD and interlock signals • INDICATION CONTACTS: 4 volt-free (SPST) latching contacts (S1-S4), rated at 120VAC/30VDC, 5mA to 5A, each configurable NO or NC to signal one of the following; open/closed or intermediate positions, moving (continuous or pulsing), Handwheel operation, local selected, remote selected, open/close interlock active, ESD active, motor tripped on torque in mid travel/going open/going closed, valve jammed, loss of power/phase or control supply, battery low, internal failure detected, thermostat tripped, programmable service alarms. • MONITOR AND AVAILABILITY RELAY: Independent relay with volt-free changeover contact, rated at 120VAC/30VDC, 5mA to 5A. De-energises in case of; loss of power/phase or control supply, local control or local stop selected (can be excluded), motor thermostat tripped or detected internal failure |
Weight: | 75 |