Msa - 10112334 19 1603 1127
Please contact us to request a price quote for Msa - 10112334 19 1603 1127 , or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Technical information
Manufacturer | Msa |
---|---|
Part number | 10112334 19 1603 1127 |
Inner Code | 589095 |
Technical specification | (PrimaX P, M25, H+R, H2S 50, Int. HART-EX-TRANSmitter im Anschlußgehäuse, explosionsgeschützt, Gehäuse aus pulverbeschichtetem Aluminium ATEX-Schutzart: Gas II 2G Ex d ia [ia] IIC T4 Gb und Dust: II 2D Ex tb ia [ia] IIIC T130°C Db IP67 -40°C<(><<)>Ta<(><<)>+55°C (Ox-Tox-Sensor +70°C) Baumusterprüfbescheinigungsnummer: BVS 10 ATEX E 009 X IECEx BVS 10.0063X N1 Gehäuseschutzart: IP 66 Meßprinzip: Elektrochemische Meßzelle Kalibriert auf: Schwefelwasserstoff (H2S) in Luft Meßbereich: 0...50 ppm Eingesteller Alarm am Transmitter: Alarm: 30 % vom Messbereich Einstellbare Alarme an der Auswerteeinheit: 1. Alarm: 5 ppm 2. Alarm: 10 ppm Am Bedienfeld einstellbare Meßbereiche: 0...10 ppm, 0...20 ppm, 0...100 ppm Anzeige: LCD Ausgänge: 4...20 mA, Alarmrelais, Störungsrelais Eigensichere HART-Schnittstelle, digitales HART-Protokoll zur Auswertung und Konfigurierung Verdrahtung: 3-adrig Zulässiger Umgebungstemperaturbereich: -40...+50°C Rel. Feuchte: 15...90% nicht kondensierend Druckbereich: 80...120 kPa Leistungsaufnahme: 24 VDC / 3 W typisch Abmessungen: H x B x T 220 x 162 x 100 mm Gewicht: 1,6 kg Enthalten: Kabelverschraubung M25x1,5 mm Ex d 9-16 mm Messing vernickelt, Spritzwasserschutz, Kalibrierkappe) |