Mecon - TL3A0-FC
Please contact us to request a price quote for Mecon - TL3A0-FC, or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Technical information
Manufacturer | Mecon |
---|---|
Part number | TL3A0-FC |
Inner Code | 4926057 |
Custom code | 90261081 |
Technical specification | Turbo-Lux 3 DN65 100 GPM KIT Description: Turbo-Lux 3 workings Measurement principle: Diaphragm as differential pressure transmitter with bypass flow meter flow direction: arbitrary, taking into account the direction of the arrow Installation position: any Measurement accuracy Measurement deviation: ±2.0% of the end value of the measurement range (FM) ± 5.0% of measurement value (LPCB) ±2.5% of the final measurement range value (vDS) process conditions Nominal size: 2 1/2"/DN 65 (ø 76.1 mm) grooved Pump rated power: 100 usGpm Inlet and outlet distance:5 x D and 2 x D Display range: 40 — 200 usGPM 150 - 750 lpm Installation length: 100 mm (+0.0 mm/-2.0 mm) operating conditions Medium: water Operating temperature: +4 to +50 °C max. operating pressure: FM 500 psi (34.5 bar) LPCB/ VdS PN 16 (232 psi) Constructive structure Case tube: stainless steel Differential pressure collection tube: brass Floater: stainless steel Bypass valve: stainless steel Filter screen: stainless steel Filter screen: stainless steel Seal: NBR Certificates/Approvals FM LPCB VdS Measurement accuracy certificate (bypass meter): with AL: N ECCN: N PREF-J: ALL |