logo

Working hours:
Mon - Fri 09:00 - 17:00

Call Us:
+44 20 80899663

Ime - MF7FTU0036 NEMO72-L

Please contact us to request a price quote for Ime - MF7FTU0036 NEMO72-L , or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.


WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

Ime-MF7FTU0036 NEMO72-L  price

Technical information

Manufacturer Ime
Part number MF7FTU0036 NEMO72-L
Inner Code 345557
Description Nemo72-L: Multifunction Display Type  , Unbalanced load is 3- or 4-wire three-phase system Panel mounting; Front frame 72x72mm² Panel cut 68x68mm² LCD display; 4 lines; Character height 5mm Display of: voltage; Electricity; Power factor; Active, reactive and apparent power; Frequency; Active and reactive power; Mean power; Average current; Harmonic content (current) Input voltage: 80 ... 500V (phase-phase) Transformer ratio programmable Power Input: transformer connection 5A (current transformer secondary must not be grounded) Transformer ratio programmable Frequency: 47 ... 63Hz Output: Pulse output for active energy Pulse duration prog. (50 ... 300ms) Pulse value prog. (1Imp / 10Wh ... 1Imp / 100kWh) Accuracy: 0.5 Kl (I, U);. Kl 1.5 (P, Q, S). . Kl 2 (active energy); Kl. 3 (reactive energy) Programmable parameters: network type; Pulse output; Power and average power Supply voltage: 230V 63Hz 47 ...
Weight: 1

Don't hesitate to contact us!

Looking for industrial spare parts?

Other Ime products

  • MF7FT40036 NEMO72-L

    , Unbalanced load is 3- or 4-wire three-phase system Panel mounting; Front frame 72x72mm² Panel cut 68x68mm² LCD display; 4 lines; Character height 5mm Display of: voltage; Electricity; Power factor; Active, reactive and apparent power; Frequency; Active and reactive power; Mean power; Average current; Harmonic content (current) Input voltage: 80 ... 500V (phase-phase) Transformer ratio programmable Power Input: transformer connection 1A (CT secondary must not be grounded) Transformer ratio programmable Frequency: 47 ... 63Hz Output: RS485 communication Protocol: JBUS / MODBUS Accuracy: 0.5 Kl (I, U);. Kl 1.5 (P, Q, S). . Kl 2 (active energy); Kl. 3 (reactive energy) Programmable parameters: network type; Communication; Power and average power Supply voltage: 230V 63Hz 47 ...

  • MF7FT40046 NEMO72-L

    Multifunction indicator Type: Nemo72-L , Unbalanced load is 3- or 4-wire three-phase system Panel mounting; Front frame 72x72mm² Panel cut 68x68mm² LCD display; 4 lines; Character height 5mm Display of: voltage; Electricity; Power factor; Active, reactive and apparent power; Frequency; Active and reactive power; Mean power; Average current; Harmonic content (current) Input voltage: 80 ... 500V (phase-phase) Transformer ratio programmable Power Input: transformer connection 5A (current transformer secondary must not be grounded) Transformer ratio programmable Frequency: 47 ... 63Hz Output: RS485 communication Protocol: JBUS / MODBUS Accuracy: 0.5 Kl (I, U);. Kl 1.5 (P, Q, S). . Kl 2 (active energy); Kl. 3 (reactive energy) Programmable parameters: network type; Communication; Power and average power Supply voltage: 230V 63Hz 47 ...

  • MF7FTU0046 NEMO72-L

    Multifunction Display Type: Nemo72-L , Unbalanced load is 3- or 4-wire three-phase system Panel mounting; Front frame 72x72mm² Panel cut 68x68mm² LCD display; 4 lines; Character height 5mm Display of: voltage; Electricity; Power factor; Active, reactive and apparent power; Frequency; Active and reactive power; Mean power; Average current; Harmonic content (current) Input voltage: 80 ... 500V (phase-phase) Transformer ratio programmable Power Input: transformer connection 5A (current transformer secondary must not be grounded) Transformer ratio programmable Frequency: 47 ... 63Hz Output: Pulse output for active energy Pulse duration prog. (50 ... 300ms) Pulse value prog. (1Imp / 10Wh ... 1Imp / 100kWh) Accuracy: 0.5 Kl (I, U);. Kl 1.5 (P, Q, S). . Kl 2 (active energy); Kl. 3 (reactive energy) Programmable parameters: network type; Pulse output; Power and average power Supply voltage: 230V 63Hz 47 ...

  • TM4I330-2

    Current Transducer

  • AN3212C100/ RQ96E

    Analoganzeiger Wechselstrom für Wandleranschluss 100/1A

  • TM4U3102

    Messumformer Wechselspannung True RMS

  • TM4I340-2

    Messumformer Wechselstrom True RMS

  • TM3ULP0 0-130,9V

    Messumformer Wechselspannung

  • TM3UL20

    Messumformer Wechselspannung

  • TM3ULP0 0-139,9V

    Messumformer Wechselspannung

  • AN3211C800 ( RQ96E)

    Analog Ammeter

  • TA42650C160

    CURRENT TRANSFORMER

  • ANTJ11

    relay

  • ANTJ10 ( SYNCRO 96C )

    LED synchroscope with synchronizing contact

  • ANTJ30 (Syncro 96C)

    LED synchroscope with synchronizing contact

  • MF6GT00076 type Nemo D4-b

    Multifunction meters

  • DER060B100

    Shunts-DER 10A/60mV