logo

Working hours:
Mon - Fri 09:00 - 17:00

Call Us:
+44 20 80899663

Bieler Lang

We offer high quality Bieler Lang products for competitive prices. Check our web range of Bieler Lang and send us an enquiry, even if you cannot find the product you are looking for there. We deliver your goods right to your doorstep.

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

Who is the official distributor or seller of Bieler Lang in United Kingdom?

Although we are not the official distributor or seller of Bieler Lang in United Kingdom, we source our products from reliable channels and offer original Bieler Lang equipment at competitive prices.

Where can I buy Bieler Lang products in United Kingdom?

You can purchase Bieler Lang products from RADWARD LTD. We offer a wide range of original Bieler Lang products to meet your industrial needs.

How can I access Bieler Lang product catalogs, user manuals, technical documents, and PDFs?

You can access catalogs, user manuals, and technical documents for Bieler Lang products on our website. Visit the resources section or contact us directly for specific documents.

Do you provide a warranty for Bieler Lang products?

Warranty terms may vary depending on the product. Please contact us for detailed information about the warranty coverage of the Bieler Lang products you are interested in.

How can I get technical support for Bieler Lang products?

While we do not offer direct technical support, we can facilitate communication between you and the manufacturer to ensure you receive the necessary assistance.

Bieler Lang logo
4 / 5
(73)
Don't hesitate to contact us!

Looking for industrial spare parts?

Bieler Lang products

  • 34 L

    with flow meter for 34l Minican

  • 822

    sensor for 86 647

  • Calibrationbox-I

    II 2 G Eex ib IIC T4,PTB 01 ATEX 2102, BAM 03 ATEX 003 Xmeasured by the sensor display of the currentConcentration of the gasesAdjustment / calibration / configuration of the sensorStoring the adjustment information forFurther processing in computer systemsAlphanumeric display, keypad for easyOperation, power supply through integratedBatteries, monitoring and display of thebattery capacityIP 54Weight: 660gDimensions HxWxD: 180x86x36mm

  • CALIBRATIONBOX-I

    II 2 G Eex ib IIC T4,PTB 01 ATEX 2102, BAM 03 ATEX 003 Xmeasured by the sensor display of the currentConcentration of the gasesAdjustment / calibration / configuration of the sensorStoring the adjustment information forFurther processing in computer systemsAlphanumeric display, keypad for easyOperation, power supply through integratedBatteries, monitoring and display of thebattery capacityIP 54Weight: 660gDimensions HxWxD: 180x86x36mm

  • Erstjustierung im Herstellerwerk auf 4 x Butan, 2 x Methan

    Initial adjustment in the factory x 4 butane, 2 x methane

  • EXDETECTOR HC 150

    Gas Detector

  • 12.100907.1

    gas measurement computer

  • 8022 E (12.600602.3)

    gas measuring computer

  • EXDETECTOR HC-100

    Ex certificates enclosure / electronics:  II 2G Ex de (ib) IIC T6 PTB 00 ATEX 1075 Measuring head: II 2G Ex de IIC T4 PTB 00 ATEX 1076U EC type examination certificate: BAM 03 ATEX 0003X SIL-1 capable Principle: Catalytic Measuring gas: u Expl gases.. fumes Range: 0 - 100% LEL Measuring signal: 4 - 20 mA Temperature range: -20 to + 55 ° C Supply: 24V DC IP 54 Design: Sensor stainless steel, aluminum housing  

  • Gasmesscomputer Typ : 8022

    (EC-type examination certificate BVS 03 ATEX G 007 X, PFG-No. 41300503P SIL-1 capable microprocessor technology Fault monitoring for wire breakage, power failure Short circuit and computer defect Cyclical, digital display of the current Concentration of each measuring point Alarm test without test gas Reset the horn and alarm 2 Alarm thresholds: 2 Connectable probe: 2 Design: wall mounting or standard mounting box LEDs for: Alarm 1 and 2, malfunction, sensor 1+ 2 Horn, operating Relay output for: Alarm 1 and 2 for both sensors Horn and fault Alarm 1 non-latching Alarm 2: optionally storing Supply voltage: 230V AC or 24V DC)

  • GASMEßFUHLER-TYP: EXDETECTOR HC 150

    for use in hazardous areas of Zone 2 Housing / Electronics: II 3G Ex nA IIC T4 de Measuring head: II 2G EEx d IIC T4 PTB 00 ATEX 1076U SIL-1 capable Principle: Catalytic Measuring gas. Expl gases and vapors Range: 0 - 100% LEL Measuring signal: 4 - 20 mA Temperature: -20 to + 55 ° C Supply: 18V DC IP 54 Housing: Housing Aluminum, stainless steel sensor

  • Gasmeßfühler-Typ: ExDetector HC-100 Butan

    II 2G Ex de (ib) IIC T6 PTB 00 ATEX 1075 Measuring head: II 2G Ex de IIC T4 PTB 00 ATEX 1076U EC type examination certificate: BAM 03 ATEX 0003X SIL-1 capable Principle: Catalytic Measuring gas: Butane Range: 0 - 100% LEL Measuring signal: 4 - 20 mA Temperature range: -20 to + 55 ° C Supply: 24V DC IP 54 Design: Sensor stainless steel, aluminum housing

  • Gasmeßfühler-Typ: ExDetector HC-100 methan (C4H10)

    II 2G Ex de (ib) IIC T6 PTB 00 ATEX 1075 Measuring head: II 2G Ex de IIC T4 PTB 00 ATEX 1076U EC type examination certificate: BAM 03 ATEX 0003X SIL-1 capable Principle: Catalytic Measuring gas: methane Range: 0 - 100% LEL Measuring signal: 4 - 20 mA Temperature range: -20 to + 55 ° C Supply: 24V DC IP 54 Design: Sensor stainless steel, aluminum housing

  • GM 813-2

    sensor

  • GMC ECOLINE 8304

    Gas Warning Center

  • 8022 (12.600534.5)

    Gas measuring computer

  • GS 7500 EX

    sensor for the measurement of alcohol

  • H2 1000

    Sensor type: Exmonitor H2-1000 Opinion II 2G Ex ia IIC t4 BVS 03 ATEX E 384 Principle: elektrochem. cell Measuring gas: Hydrogen Measuring range: 0 - 1000 ppm Measuring signal: 4 - 20 mA IP 54 Weight: 1200g Supply: 21-28V DC 2-wire, man calibration, Display current concentration Direct access to the controls, Display of the sensitivity of the sensor, When used in hazardous areas, the Use of barriers necessary

  • HC 100-K

    (Gas sensor type: ExDetector HC-100K, Ex certificates enclosure / electronics: II 2G Ex de (ib) IIC T6 PTB 00 ATEX 1075 Measuring head: II 2G Ex de IIC T4 PTB 00 ATEX 1076U EC type examination certificate: BAM 03 ATEX 0003X SIL-1 capable For installation in ventilation ducts Principle: Catalytic Measuring gas: u Expl gases.. fumes Range: 0 - 100% LEL Measuring signal: 4 - 20 mA Temperature range Housing: -20 to + 55 ° C Sensor temperature range: -20 to + 80 ° C Supply: 24V DC IP 54 Design: Sensor stainless steel, aluminum housing)

  • 12.600764.3 / HC 150

    gas sensor ExDetector HC 150

Other Category Brands